Technical Specs

  • Type
    Pressure Switch
  • Measurement Type
    Absolute
  • Full Scale Pressure Ranges
    1, 2, 10, 100, 1000 Torr (mmHg) absolute
  • Set Point Range
    0.2% to 100% of Full Scale
  • Sensor Temperature
    Ambient
  • Accuracy
    ±0.5% of Full Scale Range (± temperature coefficients)
  • Zero Temperature Coefficient
    ±0.04% of Full Scale/°C
  • Span Temperature Coefficient
    ±0.06% of set point/°C
  • Operating Temperature Range
    0° to 50°C
  • Response Time
    < 20 msec from 0 to Full Scale
  • Relay Contact Ratings
    DPDT, 2 amps @ 30 VDC or 1 amp @ 120 VAC resistive
  • Internal Volume
    7.0 cc (5K-25K Torr units have an 8.5 cc volume)
  • Overpressure
    120% of Full Scale or 35 psia (1000 mmHg), whichever is larger (1 and 2 Torr Full Scale units have a max. overpressure of 25 psia)
  • Power Requirements
    20 to 30 VDC, 72 mA
  • Compliance
    Compliant to EMC Directive 2014/30/EU

Technical Specs

  • Type
    Pressure Switch
  • Measurement Type
    Absolute
  • Full Scale Pressure Ranges
    1, 2, 10, 100, 1000 Torr (mmHg) absolute
  • Set Point Range
    0.2% to 100% of Full Scale
  • Sensor Temperature
    Ambient
  • Accuracy
    ±0.5% of Full Scale Range (± temperature coefficients)
  • Zero Temperature Coefficient
    ±0.04% of Full Scale/°C
  • Span Temperature Coefficient
    ±0.06% of set point/°C
  • Operating Temperature Range
    0° to 50°C
  • Response Time
    < 20 msec from 0 to Full Scale
  • Relay Contact Ratings
    DPDT, 2 amps @ 30 VDC or 1 amp @ 120 VAC resistive
  • Internal Volume
    7.0 cc (5K-25K Torr units have an 8.5 cc volume)
  • Overpressure
    120% of Full Scale or 35 psia (1000 mmHg), whichever is larger (1 and 2 Torr Full Scale units have a max. overpressure of 25 psia)
  • Power Requirements
    20 to 30 VDC, 72 mA
  • Compliance
    Compliant to EMC Directive 2014/30/EU

Resources & Downloads

Need help?

Contact an Applications Specialist by sending us an email