649B Downstream Pressure Controllers with Mass Flow Meter
Model: 649b-integrated-pressure-controller
649B Downstream Pressure Controllers with Mass Flow Meter
Model: 649b-integrated-pressure-controller
Technical Specs
Type
649 Pressure Controller with Capacitance Manometer and Mass Flow Meter
Pressure Range
10, 20, 50, 100, 1000 mmHg (Torr) Full Scale
Valve Orifice
50, 200, 1000, 5000 sccm (nominal Full Scale flow rates for N2 with 15 psig on inlet and atmospheric pressure on outlet)
Flow Rate
10, 20, 50, 100, 200, 500, 1000, 2000, 5000 sccm (Full Scale)
Trip Points
Pressure: Two open-collector transistors
Rated: 250 mA @ 30 VDC
Adjustable: 1 to 100% of Full Scale
Hysteresis: 3% of Full Scale
Indicators: Green LEDs on when actuated
Pressure Control Accuracy
±0.2% of Full Scale
Transducer Over Pressure Limit
45 psia or 2x Full Scale, whichever is greater
Maximum Differential Pressure
150 psi (consistent with transducer overpressure limit)
Control Mode
Downstream
Pressure Measurement Accuracy
±0.5% of Reading (includes linearity, hysteresis, and repeatability)
Zero Temperature Coefficient
±0.04% of Full Scale/°C
Span Temperature Coefficient
±0.04% of Reading/°C
Control Range
2 to 100% of Full Scale
Typical Response Time
1.0 sec (excluding system time constant)
Operating Temperature
0 to 50°C (32 to 122°F)
Storage Temperature
-20 to 80°C (-4 to 176°F)
Flow Measurement Range
1% to 100% of Full Scale
Flow Repeatability
±0.2% of Full Scale
Flow Resolution
0.1% of Full Scale
Flow Accuracy
±1.0% of Full Scale (including non-linearity, hysteresis, and non-repeatability referenced to 760 mmHg and 0°C)
Flow Span Temperature Coefficient
< 0.08% of Reading/°C
Flow Zero Temperature Coefficient
< 0.05% of Full Scale/°C
Flow Reading Pressure Coefficient
<0.02% of Reading/psi
Input Power
±15 VDC ±5%, 300 mA max.
Connector
15-pin male Type “D"
Meter Response Time
<100 msec
Meter Warm-up Time
<2 min (within 0.2% of Full Scale steady state)
RFI Sensitivity
SAMA 33.1, 1-abc: <0.2% of Full Scale
Input-Output Signals
Pressure: 0-10 VDC default (user settable to 0-5 VDC)
Cable Length
100 ft. (30 m) max.
Compliance
CE
Technical Specs
Type
649 Pressure Controller with Capacitance Manometer and Mass Flow Meter
Pressure Range
10, 20, 50, 100, 1000 mmHg (Torr) Full Scale
Valve Orifice
50, 200, 1000, 5000 sccm (nominal Full Scale flow rates for N2 with 15 psig on inlet and atmospheric pressure on outlet)
Flow Rate
10, 20, 50, 100, 200, 500, 1000, 2000, 5000 sccm (Full Scale)
Trip Points
Pressure: Two open-collector transistors
Rated: 250 mA @ 30 VDC
Adjustable: 1 to 100% of Full Scale
Hysteresis: 3% of Full Scale
Indicators: Green LEDs on when actuated
Pressure Control Accuracy
±0.2% of Full Scale
Transducer Over Pressure Limit
45 psia or 2x Full Scale, whichever is greater
Maximum Differential Pressure
150 psi (consistent with transducer overpressure limit)
Control Mode
Downstream
Pressure Measurement Accuracy
±0.5% of Reading (includes linearity, hysteresis, and repeatability)
Zero Temperature Coefficient
±0.04% of Full Scale/°C
Span Temperature Coefficient
±0.04% of Reading/°C
Control Range
2 to 100% of Full Scale
Typical Response Time
1.0 sec (excluding system time constant)
Operating Temperature
0 to 50°C (32 to 122°F)
Storage Temperature
-20 to 80°C (-4 to 176°F)
Flow Measurement Range
1% to 100% of Full Scale
Flow Repeatability
±0.2% of Full Scale
Flow Resolution
0.1% of Full Scale
Flow Accuracy
±1.0% of Full Scale (including non-linearity, hysteresis, and non-repeatability referenced to 760 mmHg and 0°C)
Flow Span Temperature Coefficient
< 0.08% of Reading/°C
Flow Zero Temperature Coefficient
< 0.05% of Full Scale/°C
Flow Reading Pressure Coefficient
<0.02% of Reading/psi
Input Power
±15 VDC ±5%, 300 mA max.
Connector
15-pin male Type “D"
Meter Response Time
<100 msec
Meter Warm-up Time
<2 min (within 0.2% of Full Scale steady state)
RFI Sensitivity
SAMA 33.1, 1-abc: <0.2% of Full Scale
Input-Output Signals
Pressure: 0-10 VDC default (user settable to 0-5 VDC)
Cable Length
100 ft. (30 m) max.
Compliance
CE