943 Vacuum Gauge Controller
Model: 943-A-120V50-PA-PC
943 Vacuum Gauge Controller
Model: 943-A-120V50-PA-PC

Overview
Overview
The 943-A-120V50-PA-PC Digital Controller for Cold Cathode Vacuum Gauges features a Pascal unit readout, and requires 100 to 120 VAC, 50 Hz power. The 943 Vacuum Gauge Controller uses a high visibility LED display. An internal converter provides output that allows a simple log conversion from voltage to pressure over the entire operating range. And a fast responding, buffered analog output is also provided through the 15 pin accessory connector on the rear panel. The 943 digital controller features two standard independent relay set points, which allows you to confidently control your process. Adjust the set points from the front panel while viewing the display. Red LEDs indicate set point activation status. Front panel functions allow the user to disable the high voltage, as well as set a pressure at which the cold cathode will automatically turn off. This prevents the controller from displaying incorrect readings when the pressure goes above the operating range of the sensor.
Technical Specs
- TypeVacuum Gauge Controller
- Measurement Range1.3 x 10-8 - 1.3 Pa
- Set Point Range2.7 x 10-7 - 1.2 Pa
- Resolution1% of indicated decade
- Operating Temperature5 - 40°C (41 - 104°F)
- Storage Temperature-10 - 55°C (14 - 104°F)
- Relative Humidity80% maximum for temperatures less than 31°C, decreasing linearly to 50% maximum at 40°C
- Altitude2000 m maximum
- Set Point Response50 msec for pressures >10-8 Torr
- Relays2 independently set, SPDT contacts
- Relay Contact Rating1 Amp @ 30 VAC or 24 VDC, resistive load
- Power Requirements100 - 120 Volts, 50 Hz
- Weight2.5 lbs. (1.1 kg)
- UnitsPascal
- DisplayRed LED, 7 segments digits 14 mm in height, ±60° viewing angle, 2 digits (1 leading) with 1.5 digit signed exponent, update rate: 250 msec
- ControlsPower on/off, set point and protect view buttons, LED set point indicators, set point and protect adjust potentiometers, high voltage on/off/remote toggle switch
- Output VoltageAnalog: 0 - 9 VDC, Logarithmic Analog: 1 - 9 VDC, 1 V per decade
- ComplianceCE
Technical Specs
- TypeVacuum Gauge Controller
- Measurement Range1.3 x 10-8 - 1.3 Pa
- Set Point Range2.7 x 10-7 - 1.2 Pa
- Resolution1% of indicated decade
- Operating Temperature5 - 40°C (41 - 104°F)
- Storage Temperature-10 - 55°C (14 - 104°F)
- Relative Humidity80% maximum for temperatures less than 31°C, decreasing linearly to 50% maximum at 40°C
- Altitude2000 m maximum
- Set Point Response50 msec for pressures >10-8 Torr
- Relays2 independently set, SPDT contacts
- Relay Contact Rating1 Amp @ 30 VAC or 24 VDC, resistive load
- Power Requirements100 - 120 Volts, 50 Hz
- Weight2.5 lbs. (1.1 kg)
- UnitsPascal
- DisplayRed LED, 7 segments digits 14 mm in height, ±60° viewing angle, 2 digits (1 leading) with 1.5 digit signed exponent, update rate: 250 msec
- ControlsPower on/off, set point and protect view buttons, LED set point indicators, set point and protect adjust potentiometers, high voltage on/off/remote toggle switch
- Output VoltageAnalog: 0 - 9 VDC, Logarithmic Analog: 1 - 9 VDC, 1 V per decade
- ComplianceCE
Resources & Downloads
Drawings & CADs
943 Cold Cathode Vacuum Gauge Controller Dimensional Drawing(202.5 kB, PDF)