AA08B Micro-Baratron® High Pressure Flow-through Pressure Transducers
Model: AA08BRDPCH2GA1
AA08B Micro-Baratron® High Pressure Flow-through Pressure Transducers
Model: AA08BRDPCH2GA1

Overview
Overview
The AA08BRDPCH2GA1 Micro-Baratron® High Pressure, Ultraclean, Flow-through Pressure Transducer offers a Full Scale measurement range of 250 psia with 4 VCR® male fittings on both ends (2.24 inch face-face), 0-10 VDC analog output, and a 9-pin Type "D" on 9" flying lead in a standard enclosure. It is ideally suited for use in delivery systems that feed ultrapure gases to critical process systems. Their wetted surfaces exposed to the gas stream have a finish of better than 5 µin Ra. These transducers exhibit superior dry-down characteristics, and contribute no particles above background. After manufacture and assembly, they are purged with ultraclean nitrogen prior to double bagging in a class 100 environment. The all-Incoloy® construction of the sensors in the AA08B allows for high overpressure tolerances that reduce errors due to line pressure spikes. High burst pressure ratings contribute to overall system safety. On existing gas cabinets and process systems, field replacement of common dial gauges or lower performance transducers is made easy due to the small size, industry standard end to-end lengths, and electrical interface choices of these transducers. The optional local integrated display provides a digital readout of the line pressure at the transducer. The display, which is available on the 1000 Torr, 100 and 250 PSIA ranges with the 0-10VDC output signal, provides a highly visible red LED display of the pressure and the units of measurement. The display can also be switched to show any of four different units (PSIA, Torr, bar, and kPa) without requiring recalibration or re-ranging of the transducer itself. It takes its power from the incoming transducer voltage, so no additional cables are required.
Technical Specs
- TypeVacuum/pressure Transducer
- ConfigurationFlow-through
- Measurement TypeAbsolute
- Full Scale Pressure250 psia
- Accuracy1.0% of Reading
- Analog Output0-10 VDC
- Fitting Type4 VCR male
- Face to Face Length2.24 in.
- Electrical Connector9-pin type D on 9 in. flying lead
- Zero Temperature Coefficient0.02% of Full Scale/°C
- Span Temperature Coefficient0.04% of Reading/°C
- Overpressure Limit375 psia
- Burst Pressure2,500 psia
- Exposed MaterialsIncoloy®
- Surface Finish≤10 µin Ra
- EnclosureStandard
- Power Requirements13-32 VDC
- Operating Temperature Range0-50°C (32-122°F)
- DisplayNo
- ComplianceCE
Technical Specs
- TypeVacuum/pressure Transducer
- ConfigurationFlow-through
- Measurement TypeAbsolute
- Full Scale Pressure250 psia
- Accuracy1.0% of Reading
- Analog Output0-10 VDC
- Fitting Type4 VCR male
- Face to Face Length2.24 in.
- Electrical Connector9-pin type D on 9 in. flying lead
- Zero Temperature Coefficient0.02% of Full Scale/°C
- Span Temperature Coefficient0.04% of Reading/°C
- Overpressure Limit375 psia
- Burst Pressure2,500 psia
- Exposed MaterialsIncoloy®
- Surface Finish≤10 µin Ra
- EnclosureStandard
- Power Requirements13-32 VDC
- Operating Temperature Range0-50°C (32-122°F)
- DisplayNo
- ComplianceCE
Resources & Downloads
Drawings & CADs