Cirrus™ 3-XD High Sensitivity Atmospheric Pressure Gas Monitors
Model: CIRRUS-3-XD
Cirrus™ 3-XD High Sensitivity Atmospheric Pressure Gas Monitors
Model: CIRRUS-3-XD

Overview
Overview
The Cirrus™3-XD Compact Benchtop and Rack-mounted Atmospheric Systems with V-lens™ Technology are designed for researchers and engineers who need to work beyond the limits of conventional quadrupole mass spectrometry gas analysis - to more easily detect and monitor trace gases - the Cirrus™ 3-XD Single-quadrupole MS Gas Analyzer delivers a unique analytical advantage for "eXtreme Detection" capability. The proven Cirrus™ Quadrupole MS platform now utilizes patented, V-lens™ ion optics with a double-focusing and deflection capability - to produce a consistently low baseline for any gas species - enabling trace level detection with greater clarity and confidence than ever before. With its versatile, compact design and powerful, automatable software control, the Cirrus™ 3-XD system provides a new level in performance, robustness and ease-of-use for the most challenging trace gas analyses. Cirrus™ gas analysis systems are ideal for on-line monitoring and analysis of gases and gas mixtures including trace contaminants in process gases, solvent vapors, hydrocarbons, atmospheric and inorganic gas species (including corrosives), freons and noble gases. Cirrus™ Single-quadrupole Mass Spectrometer Gas Analyzer systems are easy to install and operate, featuring automatic start-up and shut-down routines as well as built-in vacuum and heater interlocking for system protection. Cirrus™ 3-XD systems are manufactured from quality field proven materials which maximize reliability and uptime. Particular consideration has been paid to ease of service and maintenance.
Technical Specs
- TypeATM-pressure Gas Monitor
- Mass Range1 - 100 amu, 1 - 200 amu, or 1 - 300 amu
- Minimum Detectable ConcentrationGas and Mass Independent. The minimum detectable concentration 3 sigma baseline noise is <15 ppb (specified with Argon or Nitrogen)
- Electron Energy & Emission CurrentOperator variable
- Maximum Operating Conditions5 - 35°C, 80% RH (non-condensing) Turbo pump & electronics
- Bake Out Temperature180°C for bake out, 80°C setting for operation at elevated temperatures (vacuum chamber & inlet interface)
- Inlet2.0 m long with 0.25 in. Swagelok® end connection, heated to 150°C (optional heating to 300°C, with stainless steel only). Standard fused silica and optional stainless steel.
- Gas Consumption20 ml/min, lower uptake rate capillaries options are available
- Sample Pressure1 bar nominal
- Pumping SystemHigh compression turbo-molecular pump with internal 4-stage diaphragm backing pump standard, corrosive gas pumping with all internal pumps optional
- Automated Inlet Pressure ControllerA Baratron® capacitance manometer-based automated inlet pressure controller is available as an option
- PC RequirementsMicrosoft 32 bit or 64 bit Windows 7 or 8.1
- Interfaces1 x LAN port required
- I/O Capability4 analog inputs (-11 to +11 V, 22 bit), 2 analog outputs (0-10 V, 12 bit), 16 TTL digital I/O
- Power RequirementsUniversal mains input 100 - 240 VAC/50 - 60 Hz. Power supply specified at 700 W. Maximum consumption(during bakeout) typically 300 W
- ComplianceExempt to RoHS Directive 2002/95/EC
- DimensionsBenchtop: 593 x 291 x 470 mm, Rack-mounted: 577 x 482 x 266mm, (6U) (length x width x height)
- WeightBenchtop: 35 kg, Rack-mounted: 35 kg
- Measurement TechniqueMass Spectrometry
- DetectorDual (Faraday and Secondary Electron Multiplier)
Technical Specs
- TypeATM-pressure Gas Monitor
- Mass Range1 - 100 amu, 1 - 200 amu, or 1 - 300 amu
- Minimum Detectable ConcentrationGas and Mass Independent. The minimum detectable concentration 3 sigma baseline noise is <15 ppb (specified with Argon or Nitrogen)
- Electron Energy & Emission CurrentOperator variable
- Maximum Operating Conditions5 - 35°C, 80% RH (non-condensing) Turbo pump & electronics
- Bake Out Temperature180°C for bake out, 80°C setting for operation at elevated temperatures (vacuum chamber & inlet interface)
- Inlet2.0 m long with 0.25 in. Swagelok® end connection, heated to 150°C (optional heating to 300°C, with stainless steel only). Standard fused silica and optional stainless steel.
- Gas Consumption20 ml/min, lower uptake rate capillaries options are available
- Sample Pressure1 bar nominal
- Pumping SystemHigh compression turbo-molecular pump with internal 4-stage diaphragm backing pump standard, corrosive gas pumping with all internal pumps optional
- Automated Inlet Pressure ControllerA Baratron® capacitance manometer-based automated inlet pressure controller is available as an option
- PC RequirementsMicrosoft 32 bit or 64 bit Windows 7 or 8.1
- Interfaces1 x LAN port required
- I/O Capability4 analog inputs (-11 to +11 V, 22 bit), 2 analog outputs (0-10 V, 12 bit), 16 TTL digital I/O
- Power RequirementsUniversal mains input 100 - 240 VAC/50 - 60 Hz. Power supply specified at 700 W. Maximum consumption(during bakeout) typically 300 W
- ComplianceExempt to RoHS Directive 2002/95/EC
- DimensionsBenchtop: 593 x 291 x 470 mm, Rack-mounted: 577 x 482 x 266mm, (6U) (length x width x height)
- WeightBenchtop: 35 kg, Rack-mounted: 35 kg
- Measurement TechniqueMass Spectrometry
- DetectorDual (Faraday and Secondary Electron Multiplier)