Configuration Options

The following options are available for DA07A Baratron® Capacitance Manometers
Ordering Code Example: DA07A01TCES24BAA0V0

Configuration Option Option Code
DA07A Heated Capacitance Manometers DA07A
Full Scale Range
1 Torr or mbar 01
2 Torr or mbar 02
10 Torr or mbar 11
20 Torr or mbar 21
100 Torr or mbar 12
200 Torr or mbar 22
500 Torr or mbar 52
1000 Torr or mbar 13
Units of Measurement
Torr absolute T
mbar absolute M
Fittings
0.5 in. OD tube BA
8 VCR (compatible) female CE
8 VCR (compatible) male CF
8 VCR (compatible) female, short tube (use with sensor type T or M) CR
NW16 ISO-KF GA
1.33 in. OD CF (rotatable) HA
Sensor Type
Standard sensor, standard inlet tube length S
Standard sensor, reduced inlet tube length (use with fitting code CR) T
Deposition/etch/fluorine friendly sensor L
Short tube deposition/etch/fluorine friendly sensor (use with fitting code CR) M
Input/Output Voltages
±15 VDC input, 0-10 VDC analog output 2
24 VDC input, 0-10 VDC analog output 3
Sensor Temperature
Unheated 0
45°C 4
80°C 8
100°C 1
Electrical Connector
15-pin D-subminiature male connector with screw lock B
15-pin D-subminiature male connector with slide lock P
Trip Points
None 00
Trip A above 50%, Trip B above 50% of Full Scale Range AA
Trip A above 50%, Trip B below 50% of Full Scale Range AB
Trip A below 50%, Trip B below 50% of Full Scale Range BB
Trip A below 50%, Trip B above 50% of Full Scale Range BA
Reserved
Reserved 0
Calibration
Full Scale > 1 Torr 0
Vertical (Full Scale ≤ 1 Torr Only) V
Horizontal (Full Scale ≤ 1 Torr Only) H
Accuracy
Standard accuracy 0
Notes:
Units with trip points have default setpoints and actuation direction based on the part number code but are user adjustable through EtherCAT.
Custom part numbers can be requested for copy exact applications.
Standard part numbers will ship with the latest firmware at the date of manufacture. A custom part number should be requested for locked firmware/EtherCAT ESI file.
Description
DA07A 1-1000 Torr Heated & Unheated Baratron® Capacitance Manometers with EtherCAT®

DA07A

Unheated & Heated Absolute Baratron® Digital Capacitance Manometer w/EtherCAT®

Specifications

  • Type
    Vacuum/pressure Transducer
  • Measurement Type
    Absolute
  • Sensor Temperature
    Unheated or Controlled to 45°C, 80°C, or 100°C
  • Full Scale Pressure Ranges
    1, 2, 10, 20, 100, 200, 500, 1000 Torr or mbar
  • Accuracy
    Unheated: 0.25% of Reading
    45°C: 0.10% of Reading
    80°C & 100°C: 0.25% of Reading
    Includes non-linearity, hysteresis, and non-repeatability.
    Accuracy specification and NIST-traceable calibration points included on calibration sheet are from Full Scale to 10% of Full Scale.
  • Resolution
    0.001% Full Scale
    Theoretical resolution under ideal laboratory conditions. Actual resolution in service is usually determined by system design factors not under MKS’s control.
  • Response Time
    Pressure: 12 ms nominal (10-90% of a step response) influenced by step size and digital pressure filter setting
    EtherCAT Update Rate: Refresh Rate 1 ms
  • Fitting Type
    0.5 in. OD tube
    8 VCR (compatible) female
    8 VCR (compatible) male
    8 VCR (compatible) female, short tube
    NW16 ISO-KF
    1.33 in. OD CF (rotatable)
  • Output Signal
    Analog: 0-10 VDC into >10 kΩ load
    Digital: EtherCAT
  • Electrical Connector
    Analog: 15-pin D-subminiature male
    EtherCAT: Two (2) RJ45 female receptacles for incoming and network signals
  • Zero Temperature Coefficient
    Unheated:
    0.015% Full Scale/°C for 1 Torr
    0.010% Full Scale/°C for 2 Torr
    0.005% Full Scale/°C for 10-1000 Torr
    Heated:
    0.002% Full Scale/°C
  • Span Temperature Coefficient
    Unheated: 0.04% Reading/°C
    Heated: 0.02% Reading/°C
  • Volume
    6.3 cm3 for 0.5 in. OD tube fitting. Volumes with other fitting available on request
  • Warm-up Time
    2 hours nominal (1 hour stabilization timer for unheated)
  • Overpressure Limit
    45 psia (310 kPa)
  • Materials Exposed to Process Gases
    Inconel and Incoloy nickel alloys (Fittings are made from 300 series stainless steel)
  • Power Requirements
    Unheated:
    +24 VDC ±10% @ 150 mA
    ±15 VDC @ 180 mA
    45°C:
    +24 VDC ±10% @ 560 mA
    ±15 VDC @ 480 mA
    80°C & 100°C:
    +24 VDC ±10% @ 800 mA
    ±15 VDC @ 700 mA
  • Output Relays
    Standard:
    Two solid state relays for "sensor ready" and "device fault" status.
    Optional:
    Two optional internally mounted process pressure trip relays, solid state, independently adjustable through EtherCAT by customer at atmospheric pressure from 0.5% to 100% of Full Scale range.
    Relay hysteresis default setting of 0.5% of Full Scale and is adjustable through EtherCAT.
    Relay capacity of 0.375 amps @ 30 VDC. Relay complies with UL1577 requirements.
  • Indicators
    Multicolor status LED and two (2) red/green LEDs for EtherCAT communications status
  • Compliance
    EU27: CE
    United Kingdom: UKCA
    US: FCC 15B
    Canada: CAN ICES-3(B)/NMB-3(B)
    Australia: AS CISPR11
    South Korea: KC
    Japan: JIS C 61326-1
    Taiwan: CNS 13803
    EtherCAT: ETG.5003.2080 S (R) V1.30n Vacuum Pressure Gauge
    When connected to a properly shielded cable, grounded at both ends.