MKS High Flow Valves (HFVs) increase system uptime due to their high cycle count lifetime of 1,000,000 cycles in clean environments and high conductance which allows for faster system pumping. An edge welded stainless steel bellows prevents outgassing and virtual leaks. The bellows stroke length is optimized to assure maximum conductance. The HFVs are designed to be easily and completely disassembled in the field, lowering the cost of replacing parts.
- Edge welded bellows provide maximum stroke length with high conductance
- Bellows-sealed poppet ensures a minimum of 1,000,000 cycles
- 304 stainless steel body, heatable to 160°C
- Can be mounted vertically or horizontally to accommodate footprint requirements See All Features
Configuration Options
The following options are available for HFV High Flow Vacuum Isolation Valves
Ordering Code Example: V-250-AM-NVXXX
| Configuration Option | Option Code |
|---|---|
| HFV Vacuum Isolation Valve | V |
| Valve Size | |
| NW100 (4 in. valve) | 100 |
| NW160 (6 in. valve) | 160 |
| NW200 (8 in. valve) | 200 |
| NW250 (10 in. valve) | 250 |
| Body Configuration | |
| Angle Body | A |
| Flange Type | |
| ISO-MF | M |
| Limit Switch | |
| Limit Switch | L |
| No Limit Switch | N |
| Seal Type | |
| Viton® | V |
| Kalrez® | K |
| Chemraz® | Z |
| Heater | |
| No Heater* | XXX |
| Solenoid | |
| 12 VDC | 12D |
| 24 VDC | 24D |
| 24 VAC 50/60 Hz | 24A |
| 120 VAC 50/60 Hz | 120 |
| 240 VAC 50/60 Hz | 240 |
| 1/4 in. Tube Fittings | T25 |
| 1/4 in. Tube Fittings | T38 |
| 1/4 in. NPT Ports | None |
*Heated options are available. Please consult factory for ordering information.
Specifications
- TypeHigh Conductance Vacuum Valve
- Vacuum RangeAtmosphere to 1.0 x 10-9 Torr
- Body ConfigurationAngle, Inline
- Port SizeNW100, NW160, NW200, NW250
- Helium Leak Rate1.0 x 10-9 std cc/sec
- Cylinder Air Pressure60-100 psig
- Limit Switch Rating5A - 250 VAC
- Single Pole, Single Throw5A - 30 VDC
- Closing Time0.300 - 0.750, depending on configuration
- Typical Life1,000,000 cycles
- Weight12 - 55 pounds, depending on configuration
Features
Heated Valves
HFVs are available with MKS heater solutions which ensure uniform internal temperature profiles to minimize condensation of process gases. An Ultem insulating barrier between the Festo™ actuator and valve body keeps heat inside the valve and away from the actuator. To accommodate process needs for high temperature or chemical resistance, a variety of elastomer seals are offered, including, Viton®, Chemraz®, and Kalrez®. Like all MKS isolation valves the HFV is offered with air solenoids for pneumatic actuation and limit switches for remote indication of the valve’s position.
Accessories
Replacement Solenoids/Actuators
Valve Seals
| Compare | Description | Drawings, CAD & Specs | Avail. | Price | ||
|---|---|---|---|---|---|---|
![]() | 20025912-001Viton Seal Set, HFV High Flow and High Conductance Valve, NW100 Port | |||||
![]() | 20025913-001Kalrez Seal Set, HFV High Flow and High Conductance Valve, NW100 Port | |||||
![]() | 20025914-001Chemraz Seal Set, HFV High Flow and High Conductance Valve, NW100 Port | |||||
![]() | 100016283Kalrez Seal Set, HFV High Flow and High Conductance Valve, NW160 Port | |||||
![]() | 100016282Viton Seal Set, HFV High Flow and High Conductance Valve, NW160 Port | |||||
![]() | 100016284Chemraz Seal Set, HFV High Flow and High Conductance Valve, NW160 Port | |||||
![]() | 100016285Perlast Seal Set, HFV High Flow and High Conductance Valve, NW160 Port | |||||
![]() | 100016286Viton Seal Set, HFV High Flow and High Conductance Valve, NW200 Port | |||||
![]() | 100016287Kalrez Seal Set, HFV High Flow and High Conductance Valve, NW200 Port | |||||
![]() | 100016290Viton Seal Set, HFV High Flow and High Conductance Valve, NW250 Port | |||||
![]() | 100016288Chemraz Seal Set, HFV High Flow and High Conductance Valve, NW200 Port | |||||
![]() | 100016289Perlast Seal Set, HFV High Flow and High Conductance Valve, NW200 Port | |||||
![]() | 100016380Chemraz Seal Set, HFV High Flow and High Conductance Valve, NW250 Port | |||||
![]() | 100016379Kalrez Seal Set, HFV High Flow and High Conductance Valve, NW250 Port | |||||
![]() | 100016381Seal Set, Perlast, HFV High Flow, High Conductance Valve, NW250 Port |
Limit Switches
| Compare | Description | Drawings, CAD & Specs | Avail. | Price | ||
|---|---|---|---|---|---|---|
![]() | 100016226Limit Switch Kit, HFV High Flow/High Conductance Valves, NW100, NW160, NW200, NW250 |
Internal Rebuild Kits
| Compare | Description | Drawings, CAD & Specs | Avail. | Price | ||
|---|---|---|---|---|---|---|
![]() | 1084830-001Valve Bellows, HFV High Flow/High Conductance Valve, NW100 | |||||
![]() | 100016258Valve Bellows, HFV High Flow/High Conductance Valve, NW160 | |||||
![]() | 100016261Valve Nosepiece, HFV High Flow/High Conductance Valves, NW160 | |||||
![]() | 100016278Valve Nosepiece, HFV High Flow/High Conductance Valves, NW200 | |||||
![]() | 100016279Valve Rebuild Kit, HFV High Flow/High Conductance Valve, NW160 Port | |||||
![]() | 100016362Valve Bellows, HFV High Flow/High Conductance Valve, NW200 or NW250 | |||||
![]() | 100016281Valve Rebuild Kit, HFV High Flow/High Conductance Valves, NW250 | |||||
![]() | 100016280Valve Rebuild Kit, HFV High Flow/High Conductance Valves, NW200 | |||||
![]() | 100016365Valve Nosepiece, HFV High Flow/High Conductance Valve, NW250 Port | |||||
![]() | 1084882Valve Actuator, HFV High Flow and High Conductance Valve, NW100 |
Other Accessories
| Compare | Description | Drawings, CAD & Specs | Avail. | Price | ||
|---|---|---|---|---|---|---|
![]() | 20010240-001Service Tool, HFV High Flow and High Conductance Valve, NW100 Port | |||||
![]() | 100016382Service Tool, HFV High Flow and High Conductance Valve, NW160 Port | |||||
![]() | 100016383Service Tool, HFV High Flow and High Conductance Valve, NW200 Port | |||||
![]() | 100016384Service Tool, HFV High Flow and High Conductance Valve, NW250 Port |