Dissolved Carbon Dioxide (DI-CO2) Ultrapure Water Delivery System
Model: carbonated-ultrapure-water-delivery-system
Dissolved Carbon Dioxide (DI-CO2) Ultrapure Water Delivery System
Model: carbonated-ultrapure-water-delivery-system
Technical Specs
Type
Carbon Dioxide Ultrapure Water Delivery System
Flow Rate
Minimum total flow: 0.5 L/min (0.1 gpm)
Maximum total flow: 60L/min (15.8gpm)
Communication
Binary in/out (dry contacts)
RS232, analog out
USB
Power Requirements
24 VDC/60W
Accuracy
Typical maximum deviation from set point:
Steady state flow: ±3%
Fluctuating flow: ±10% for flow changes <4 L/min per sec
UPW Temperature Range
20 - 50°C
Outlet Pressure
1.0 - 3.0 barg (0.1 - 0.3 MPag, 14.5 - 43.5 psig), depending on UPW supply pressure
Conductivity/Resistivity Range
Minimum conductivity 5 µS/cm, max. resistivity 200 kOhm*cm
Maximum conductivity 50 µS/cm, min resistivity 20 kOhm*cm
Plumbing Materials
Liquid contacted surfaces: PFA, PVDF
Cabinet Material
PVDF or C-PVC or FRPP
Dimensions
386 x 650 x 232 mm (WxHxD)
Weight
17.3 kg
Technical Specs
Type
Carbon Dioxide Ultrapure Water Delivery System
Flow Rate
Minimum total flow: 0.5 L/min (0.1 gpm)
Maximum total flow: 60L/min (15.8gpm)
Communication
Binary in/out (dry contacts)
RS232, analog out
USB
Power Requirements
24 VDC/60W
Accuracy
Typical maximum deviation from set point:
Steady state flow: ±3%
Fluctuating flow: ±10% for flow changes <4 L/min per sec
UPW Temperature Range
20 - 50°C
Outlet Pressure
1.0 - 3.0 barg (0.1 - 0.3 MPag, 14.5 - 43.5 psig), depending on UPW supply pressure
Conductivity/Resistivity Range
Minimum conductivity 5 µS/cm, max. resistivity 200 kOhm*cm
Maximum conductivity 50 µS/cm, min resistivity 20 kOhm*cm
Plumbing Materials
Liquid contacted surfaces: PFA, PVDF
Cabinet Material
PVDF or C-PVC or FRPP
Dimensions
386 x 650 x 232 mm (WxHxD)
Weight
17.3 kg
Resources & Downloads
Literature
Drawings & CADs