MultiGas™ 2030 FTIR Gas Analyzers
Model: multigas-2030g-ftir-gas-analyzer
MultiGas™ 2030 FTIR Gas Analyzers
Model: multigas-2030g-ftir-gas-analyzer
Technical Specs
Type
FTIR Analyzer
Measurement Technique
FTIR Spectrometry
Measurable Gases & Vapors
Most molecules except for He, Ar, N2, H2, and O2
Measurable Range
Concentration setting between 10ppb and 100% Full Scale
FTIR
2102 Process FTIR
Spectral Resolution
0.5 – 16 cm-1
Scan Speed
1 scan/sec @ 0.5 cm-1
Scan Time
1 - 300 sec
Infrared Source
Silicon Carbide
Reference Laser
Helium Neon (15798.2 cm-1)
Detector
LN-cooled MCT; TE-cooled MCT
Purge Pressure
20 psig (1.5 bar) max.
Spectrometer Purge Flow
0.2 L/min of dry nitrogen or CO2 free clean dry air with dewpoints below -70°C
Optics Purge Flow
0.2 L/min of dry nitrogen or CO2 free clean dry air with dewpoints below -70°C
Pressure Transducer
MKS Baratron capacitance manometer
Purge Connection
Swagelok quick connect
Communication
RJ-45 Ethernet
Dimensions
17.5 x 12.5 x 25.5 in. (width, height, depth)
Power Requirements
120 or 240 VAC, 50/60 Hz, 3 Amps
Weight
110 lbs. (50 kg)
Sample Temperature
Ambient to 191°C (calibration temperature dependent)
Sample Flow
0.2 - 60 LPM (model code dependent)
Sample Pressure
0.01 - 4 atm (calibration pressure dependent)
Gas Cell Materials
Nickel coated Al, Welded 316 stainless steel optional, dursan coating
Fittings
0.25 in. Swagelok, 0.25 in. VCR
Tubing
Heated 0.25 in. stainless steel, Heated 0.375 in. stainless steel
Mirrors
Nickel plated aluminum substrate, with rugged gold coating
Windows
ZnSe, CaF, BaF2, (others available)
O-rings
Kalrez, Viton (others available)
Technical Specs
Type
FTIR Analyzer
Measurement Technique
FTIR Spectrometry
Measurable Gases & Vapors
Most molecules except for He, Ar, N2, H2, and O2
Measurable Range
Concentration setting between 10ppb and 100% Full Scale
FTIR
2102 Process FTIR
Spectral Resolution
0.5 – 16 cm-1
Scan Speed
1 scan/sec @ 0.5 cm-1
Scan Time
1 - 300 sec
Infrared Source
Silicon Carbide
Reference Laser
Helium Neon (15798.2 cm-1)
Detector
LN-cooled MCT; TE-cooled MCT
Purge Pressure
20 psig (1.5 bar) max.
Spectrometer Purge Flow
0.2 L/min of dry nitrogen or CO2 free clean dry air with dewpoints below -70°C
Optics Purge Flow
0.2 L/min of dry nitrogen or CO2 free clean dry air with dewpoints below -70°C
Pressure Transducer
MKS Baratron capacitance manometer
Purge Connection
Swagelok quick connect
Communication
RJ-45 Ethernet
Dimensions
17.5 x 12.5 x 25.5 in. (width, height, depth)
Power Requirements
120 or 240 VAC, 50/60 Hz, 3 Amps
Weight
110 lbs. (50 kg)
Sample Temperature
Ambient to 191°C (calibration temperature dependent)
Sample Flow
0.2 - 60 LPM (model code dependent)
Sample Pressure
0.01 - 4 atm (calibration pressure dependent)
Gas Cell Materials
Nickel coated Al, Welded 316 stainless steel optional, dursan coating
Fittings
0.25 in. Swagelok, 0.25 in. VCR
Tubing
Heated 0.25 in. stainless steel, Heated 0.375 in. stainless steel
Mirrors
Nickel plated aluminum substrate, with rugged gold coating
Windows
ZnSe, CaF, BaF2, (others available)
O-rings
Kalrez, Viton (others available)