PPCMA Downstream Pressure Controller with Mass Flow Meter
Model: ppcma-integrated-pressure-controller
PPCMA Downstream Pressure Controller with Mass Flow Meter
Model: ppcma-integrated-pressure-controller

Overview
Overview
Technical Specs
- TypePPCMA Absolute Pressure Controller with Mass Flow Meter
- Pressure Range5, 10, 20, 50, 100, 200, 500 or 1000 Torr Full Scale
- Fitting TypeSwagelok® 4 VCR® Male
1.5 inch surface mount (C-seal) - Valve PositionNormally Closed
- Valve SeatPTFE (Teflon®), Elastomer (Viton®), Buna, Neoprene, EPDM
- Flow Rate5, 10, 20, 50, 100, 200, 500, 1000, 2000, 5000 (N2 equivalent)
- Pressure Readout UnitsTorr, kPa, mBar, psi
- Pressure Resolution0.1 Torr
- Pressure Control Accuracy±1.0% of Reading (≥10% Full Scale)
±0.2% of Full Scale (<10% Full Scale) - Transducer Over Pressure Limit2x Full Scale for all ranges
- Maximum Differential Pressure45 psid
- Burst Pressure1500 psig
- Control ModeDownstream
- Pressure Measurement Accuracy±0.5% of Reading
- Zero Temperature Coefficient±0.02% of Full Scale/°C
- Span Temperature Coefficient±0.04% of Reading/°C
- Control Range>5 to 100% of Full Scale
- Typical Response Time<1.0 second (excluding system time constant)
- Operating Temperature10-50°C (50 to 122°F)
- Storage Temperature-20 to 80°C (-4 to 176°F)
- Storage Humidity0 to 95% Relative Humidity, non-condensing
- External Leak Integrity<1 x 10-10 (scc/sec He)
- Leak Integrity Through Closed Valve<1.0% of orifice Full Scale
(Nitrogen at 25 psig on inlet to atmosphere)
(Nitrogen at 25 psig on inlet to atmosphere)
<0.1% of orifice Full Scale - Elastomer - Flow Measurement Range2% to 100% of Full Scale
- Flow Repeatability±0.3% of Reading
- Flow Resolution0.1% of Full Scale
- Flow Accuracy±1.0% of Reading >20% of Full Scale; ±0.2% of Full Scale (<20% of Full Scale flow)
(including non-linearity, hysteresis, and non-repeatability referenced to 760 mmHg and 0°C) - Flow Span Temperature CoefficientSpan: <0.08% of Reading/°C
- Flow Zero Temperature CoefficientZero: <0.05% of Full Scale/°C
- Wetted MaterialsStandard: 316L S.S. VAR (equivalent to 316 S.S. SCQ for semiconductor quality), 316 S.S., Elgiloy®, KM-45, Inconel® 718, 825 Incoloy®
Optional: PTFE (Teflon) or Elastomer (Viton) - Surface Finish<10 µinches, average Ra electropolished
- Power RequiredDeviceNet™: +11 to +25 VDC per (<4 watts)
EtherCAT®: +24 VDC (<5 watts) - Connector-InterfaceDeviceNet™: 5 pin micro connector (power and comm.)
EtherCAT®: 2 x RJ-45 (comm.) male, M8 male, 5 pin (power) - Data Rate SwitchDeviceNet™: 4 positions: 125, 250, 500K (Default), (programmable over network)
EtherCAT®: No switch - EtherCAT Communication Rate100 Mbps
- DeviceNet Communication Rate125 Kbps, 250 Kbps, 500 Kbps
- MAC ID SwitchesDeviceNet™: 2 switches, 10 positions: 0,0 to 6,3, 1 to 254
EtherCAT®: 3 switches, 16 positions - Network SizeDeviceNet™: Up to 64 nodes
EtherCAT®: Up to 4095 nodes - IndicatorsDeviceNet™: LED Network (green/red), LED Module (green/red)
EtherCAT®: LED Power (green), LED Run (green), LED Error (red), LED Comm (green) - Weight<5 lbs (1.36 kg)
- ComplianceCE
Technical Specs
- TypePPCMA Absolute Pressure Controller with Mass Flow Meter
- Pressure Range5, 10, 20, 50, 100, 200, 500 or 1000 Torr Full Scale
- Fitting TypeSwagelok® 4 VCR® Male
1.5 inch surface mount (C-seal) - Valve PositionNormally Closed
- Valve SeatPTFE (Teflon®), Elastomer (Viton®), Buna, Neoprene, EPDM
- Flow Rate5, 10, 20, 50, 100, 200, 500, 1000, 2000, 5000 (N2 equivalent)
- Pressure Readout UnitsTorr, kPa, mBar, psi
- Pressure Resolution0.1 Torr
- Pressure Control Accuracy±1.0% of Reading (≥10% Full Scale)
±0.2% of Full Scale (<10% Full Scale) - Transducer Over Pressure Limit2x Full Scale for all ranges
- Maximum Differential Pressure45 psid
- Burst Pressure1500 psig
- Control ModeDownstream
- Pressure Measurement Accuracy±0.5% of Reading
- Zero Temperature Coefficient±0.02% of Full Scale/°C
- Span Temperature Coefficient±0.04% of Reading/°C
- Control Range>5 to 100% of Full Scale
- Typical Response Time<1.0 second (excluding system time constant)
- Operating Temperature10-50°C (50 to 122°F)
- Storage Temperature-20 to 80°C (-4 to 176°F)
- Storage Humidity0 to 95% Relative Humidity, non-condensing
- External Leak Integrity<1 x 10-10 (scc/sec He)
- Leak Integrity Through Closed Valve<1.0% of orifice Full Scale
(Nitrogen at 25 psig on inlet to atmosphere)
(Nitrogen at 25 psig on inlet to atmosphere)
<0.1% of orifice Full Scale - Elastomer - Flow Measurement Range2% to 100% of Full Scale
- Flow Repeatability±0.3% of Reading
- Flow Resolution0.1% of Full Scale
- Flow Accuracy±1.0% of Reading >20% of Full Scale; ±0.2% of Full Scale (<20% of Full Scale flow)
(including non-linearity, hysteresis, and non-repeatability referenced to 760 mmHg and 0°C) - Flow Span Temperature CoefficientSpan: <0.08% of Reading/°C
- Flow Zero Temperature CoefficientZero: <0.05% of Full Scale/°C
- Wetted MaterialsStandard: 316L S.S. VAR (equivalent to 316 S.S. SCQ for semiconductor quality), 316 S.S., Elgiloy®, KM-45, Inconel® 718, 825 Incoloy®
Optional: PTFE (Teflon) or Elastomer (Viton) - Surface Finish<10 µinches, average Ra electropolished
- Power RequiredDeviceNet™: +11 to +25 VDC per (<4 watts)
EtherCAT®: +24 VDC (<5 watts) - Connector-InterfaceDeviceNet™: 5 pin micro connector (power and comm.)
EtherCAT®: 2 x RJ-45 (comm.) male, M8 male, 5 pin (power) - Data Rate SwitchDeviceNet™: 4 positions: 125, 250, 500K (Default), (programmable over network)
EtherCAT®: No switch - EtherCAT Communication Rate100 Mbps
- DeviceNet Communication Rate125 Kbps, 250 Kbps, 500 Kbps
- MAC ID SwitchesDeviceNet™: 2 switches, 10 positions: 0,0 to 6,3, 1 to 254
EtherCAT®: 3 switches, 16 positions - Network SizeDeviceNet™: Up to 64 nodes
EtherCAT®: Up to 4095 nodes - IndicatorsDeviceNet™: LED Network (green/red), LED Module (green/red)
EtherCAT®: LED Power (green), LED Run (green), LED Error (red), LED Comm (green) - Weight<5 lbs (1.36 kg)
- ComplianceCE
Resources & Downloads
Manuals
PPCA/PPCMA Manual(2 MB, PDF) PPCA/PPCMA DeviceNet™ Profile(572.1 kB, PDF) P-Series EtherCAT Supplement Manual (1080037-001)(296.4 kB, PDF)
Literature