PVS6F Portable Vacuum Calibration System
Model: pvs6f-calibration-system
PVS6F Portable Vacuum Calibration System
Model: pvs6f-calibration-system

Overview
Overview
Technical Specs
- TypePortable Vacuum Calibration System
- Transfer StandardAA06A absolute sensors (NIST traceable)
- Accuracy0.08% of Reading (± temp. coefficients)
Optional 0.05% of Reading (± temp. coefficients) for 1, 10, 100, or 1000 mmHg Full Scale - Resolution1 x 10-6
- Fitting TypeTest Gas Inlet: 0.25 in. Swagelok® bulkhead
Test Port (3): Swagelok 8 VCR® male (3) - Operating Temperature15-40°C
- ReadoutMKS 670, 5½-digit LCD (one per standard)
Unit under test readout electronics: PDR2000 - Power Requirements110 VAC, 60 Hz; 220 VAC, 50 Hz; 15 Amps
- Warm-up Time4 hours. However, use of the internal 500 VA UPS will keep the Transfer Standards warmed up and ready for immediate use for at least 60 minutes.
- WeightApproximately 250 lbs (110 kg)
- Pressure ControlManual needle valve to control gas inlet; manual isolation valve and metering bypass valve for pressure throttle control
- ComplianceCE
- High Vacuum GaugeIMAG ionization gauge and controller provides 1 x 10-3 to 1 x 10-9 mmHg measurement
- Standby Power500 V.A. uninterruptible power supply keeps three Transfer Standards warmed up and ready to use for up to 60 min.
- Test/Calibration5-10 psig dry filtered N2
- Vacuum Pumping SystemMechanical Pump: Oil free 4 stage diaphragm pump operated as dual two stage diaphragm pumps
High Vacuum Pump: Hybrid turbo/drag air-cooled
Normal Base Pressure: <5 x 10-7 mmHg
Technical Specs
- TypePortable Vacuum Calibration System
- Transfer StandardAA06A absolute sensors (NIST traceable)
- Accuracy0.08% of Reading (± temp. coefficients)
Optional 0.05% of Reading (± temp. coefficients) for 1, 10, 100, or 1000 mmHg Full Scale - Resolution1 x 10-6
- Fitting TypeTest Gas Inlet: 0.25 in. Swagelok® bulkhead
Test Port (3): Swagelok 8 VCR® male (3) - Operating Temperature15-40°C
- ReadoutMKS 670, 5½-digit LCD (one per standard)
Unit under test readout electronics: PDR2000 - Power Requirements110 VAC, 60 Hz; 220 VAC, 50 Hz; 15 Amps
- Warm-up Time4 hours. However, use of the internal 500 VA UPS will keep the Transfer Standards warmed up and ready for immediate use for at least 60 minutes.
- WeightApproximately 250 lbs (110 kg)
- Pressure ControlManual needle valve to control gas inlet; manual isolation valve and metering bypass valve for pressure throttle control
- ComplianceCE
- High Vacuum GaugeIMAG ionization gauge and controller provides 1 x 10-3 to 1 x 10-9 mmHg measurement
- Standby Power500 V.A. uninterruptible power supply keeps three Transfer Standards warmed up and ready to use for up to 60 min.
- Test/Calibration5-10 psig dry filtered N2
- Vacuum Pumping SystemMechanical Pump: Oil free 4 stage diaphragm pump operated as dual two stage diaphragm pumps
High Vacuum Pump: Hybrid turbo/drag air-cooled
Normal Base Pressure: <5 x 10-7 mmHg
Resources & Downloads
Literature
PVS6F Portable Vacuum Calibration System (Archive)(2.2 MB, PDF)