AA07B Micro-Baratron High Pressure Single-ended Pressure Transducers
Model: AA07B13PCD2GA1
AA07B Micro-Baratron High Pressure Single-ended Pressure Transducers
Model: AA07B13PCD2GA1

Overview
Overview
The AA07B13PCD2GA1 Micro-Baratron® High Pressure, Ultraclean, Single-ended Pressure Transducer offers 1000 psia pressure measurement with accuracy of 1.0% of Reading and a 4 VCR-style female fitting. Electrical connections for the +13 to +32 VDC power requirements and 0-10 VDC output with a 9-pin type "D" subminiature connector at the end of a 9 inch cable. It is ideally suited for use in delivery systems that feed ultrapure gases to critical process systems. Their wetted surfaces exposed to the gas stream have a finish of better than 5 µin Ra. These transducers exhibit superior dry-down characteristics, and contribute no particles above background. On existing gas cabinets and process systems, field replacement of common dial gauges or lower performance transducers is made easy due to the small size, industry standard end to-end lengths, and electrical interface choices of these transducers.
Technical Specs
- TypeVacuum/pressure Transducer
- ConfigurationSingle-ended
- Measurement TypeAbsolute
- Full Scale Pressure1000 psia
- Accuracy1.0% of Reading
- Analog Output0-10 VDC
- Fitting Type4 VCR female
- Electrical Connector9-pin Type D on 9 in. flying lead
- Zero Temperature Coefficient0.02% of Full Scale/°C
- Span Temperature Coefficient0.04% of Reading/°C
- Overpressure Limit1,200 psia
- Burst Pressure5,000 psia
- Exposed MaterialsIncoloy®
- Surface Finish≤10 µin Ra
- EnclosureNEMA 4
- Power Requirements13-32 VDC
- Operating Temperature Range0-50°C (32-122°F)
- DisplayNo
- ComplianceCE
Technical Specs
- TypeVacuum/pressure Transducer
- ConfigurationSingle-ended
- Measurement TypeAbsolute
- Full Scale Pressure1000 psia
- Accuracy1.0% of Reading
- Analog Output0-10 VDC
- Fitting Type4 VCR female
- Electrical Connector9-pin Type D on 9 in. flying lead
- Zero Temperature Coefficient0.02% of Full Scale/°C
- Span Temperature Coefficient0.04% of Reading/°C
- Overpressure Limit1,200 psia
- Burst Pressure5,000 psia
- Exposed MaterialsIncoloy®
- Surface Finish≤10 µin Ra
- EnclosureNEMA 4
- Power Requirements13-32 VDC
- Operating Temperature Range0-50°C (32-122°F)
- DisplayNo
- ComplianceCE
Resources & Downloads
Drawings & CADs
AA07 & AA08 Baratron® Pressure Transducer Dimensional Drawing(1,009.5 kB, PDF)