- Single-ended configuration for branch pressure measurement
- Incoloy® wetted surface for superior corrosive gas & liquid compatibility
- Highest overpressure ratio tolerances on the market
- Accuracy specified in percentage of reading for superior results in lower pressure ranges
- Capacitance technology at a competitive price See All Features
| Compare | Description | Drawings, CAD & Specs | Avail. | Price | ||
|---|---|---|---|---|---|---|
![]() | AA07B12PBB2GT1Pressure Transducer, 100 psia, Single-end, 0-10 VDC, 0.25 in. Tube, LDM-C, 15-pin HD | |||||
![]() | AA07B12PCB4GF4Pressure Transmitter, 100 psia, Single-end, 4-20 mA, 4 VCR Male, Flying Leads | |||||
![]() | AA07B12PCD2GA1Pressure Transducer, 100 psia, Single-end, 0-10 VDC, 4 VCR Female, DB9 on 9 in. Flying Lead | |||||
![]() | AA07B13PCB2GA1Pressure Transducer, 1000 psia, Single-end, 0-10 VDC, 4 VCR-M, DB9 on 9 in. Flying Lead | |||||
![]() | AA07B13PCD2GA1Pressure Transducer, 1000 psia, Single-end, 0-10 VDC, 4 VCR-F, DB9 on 9 in. Flying Lead | |||||
![]() | AA07B13TCB3GA1Pressure Transducer, 1000 Torr, Single-end, 0-5 VDC, 4 VCR-M, DB9 on 9 in. Flying Lead | |||||
![]() | AA07B13TCD2GC1Pressure Transducer, 1000 Torr, Single-end, 0-10 VDC, 4 VCR-F, 15-pin HD on 9 in. Flying Lead | |||||
![]() | AA07B33PBD4GL4Pressure Transmitter, 3000 psia, Single-end, 4-20 mA, 0.25 in. Weld T, Flying Leads | |||||
![]() | AA07B33PCD2GA1Pressure Transducer, 3000 psia, Single-end, 0-10 VDC, 4 VCR-F, DB9 on 9 in. Flying Lead | |||||
![]() | AA07BRDPCD2GA1Pressure Transducer, 250 psia, Single-end, 0-10 VDC, 4 VCR Female, DB9 on 9 in. Flying Lead |
Configuration Options
The following options are available for the AA07B Micro-Baratron® High Pressure Single-end Pressure Transducer.
Ordering Code Example: AA07B33PCB2GA1
| Configuration Option | Option Code |
|---|---|
| AA07B Single-ended Pressure Transducer | AA07B |
Pressure Range Full Scale* |
|
| 1000 Torr | 13T |
| 100 psia | 12P |
| 250 psia | RDP |
| 1000 psia | 13P |
| 3000 psia | 33P |
Fittings |
|
| ½” weld stub | BA |
| ¼” weld stub | BB |
| ¼” Butt-welded “T” | BD |
| 4 VCR male, rotatable | CB |
| 4 VCR female | CD |
Analog Output |
|
| 0-10 VDC | 2 |
| 0-5 VDC | 3 |
| 4-20 mA | 4 |
| Accuracy | |
| 1% of Reading | G |
Connectors |
|
| 9-pin type D at end of 9” flying lead | A |
| 15-pin high density type D at end of 9” flying lead | C |
| Bendix 4-pin at end of 9” flying lead | D |
| 6’ flying leads | F |
| 10’ flying leads | L |
| Bendix 4-pin 4-20 mA on pins A&B | H |
| LDM-C (Red LED), 0-5 VDC and 0-10 VDC with high density D connector | T |
| LDM-C (with Blank Cover), 0-5 VDC and 0-10 VDC with high density D connector | W |
Environmental |
|
| Standard enclosure (indoor use) | 1 |
| Optional NEMA 4 enclosure for water, ice and dust | 4 |
* Other engineering units available (i.e. KPa). Consult Applications Engineering for additional information
Specifications
- TypePressure Transducer
- ConfigurationSingle-ended
- Measurement TypeAbsolute
- Accuracy1.0% of Reading
- Zero Temperature Coefficient0.02% of Full Scale/°C, 50 psia to 3000 psia
0.04% of Full Scale/°C, 1000 Torr - Span Temperature Coefficient0.04% of Reading/°C, 50 psia to 3000 psia
0.08% of Reading/°C, 1000 Torr - Overpressure Limit1.5 x Full Scale for ranges from 1000 Torr to 500 psi
1.2 x Full Scale for ranges from 501 to 3000 psi
- Burst Pressure10 x Full Scale for ranges from 1000 Torr to 500 psi
5 x Full Scale for ranges from 501 to 3000 psi - Exposed MaterialsIncoloy®
- Surface Finish≤10 µin Ra
- Power Requirements13 to 32 VDC @ 10 mA max.
- Operating Temperature Range0-50°C
- ComplianceCE
Features
Baratron® Capacitance Manometer Technology
Capacitance manometers are electro-mechanical gauges that can measure both pressure and vacuum. The capacitance gauge translates a pressure-modulated movement in a thin diaphragm into an electrical signal proportional to the pressure. The pressure sensor is the thin diaphragm that is exposed to the pressure or vacuum being measured via the inlet tube. An electrode is mounted in the reference cavity behind the diaphragm. Pressure differences between the process and the reference cavity deflect the diaphragm slightly, changing the distance between it and the electrode. Variations in this distance produce variations in the capacitance between the diaphragm and the electrode creating an electrical signal that is proportional to the pressure change. Since differences in the capacitance signal are produced by physical changes within the manometer and not by changes in the gas properties, pressure measurements by the capacitance manometer are independent of the composition of the gas being measured.
Ideally Suited for Ultrapure Gas Delivery Systems
The AA07/AA08 transducers are ideally suited for use in delivery systems that feed ultrapure gases to critical process systems. Their wetted surfaces exposed to the gas stream have a finish of better than 5 µin Ra. These transducers exhibit superior dry-down characteristics, and contribute no particles above background. After manufacture and assembly, they are purged with ultraclean nitrogen prior to double bagging in a class 100 environment.
All Incoloy® Construction
The all-Incoloy® construction of the sensors in the AA07/AA08 allow for high overpressure tolerances that reduce errors due to line pressure spikes. High burst pressure ratings contribute to overall system safety. On existing gas cabinets and process systems, field replacement of common dial gauges or lower performance transducers is made easy due to the small size, industry standard endto-end lengths, and electrical interface choices of these transducers.
Optional Local Display
The optional local integrated display provides a digital readout of the line pressure at the transducer. The display, which is available on the 1000 Torr, 100 and 250 PSIA ranges with the 0-10 VDC output signal, provides a highly visible red LED display of the pressure and the units of measurement. The display can also be switched to show any of four different units (PSIA, Torr, bar, and kPa) without requiring recalibration or re-ranging of the transducer itself. It takes its power from the incoming transducer voltage, so no additional cables are required.
Resources
Literature
AA07B, AA08B Micro-Baratron® Pressure Transducers(2.2 MB, PDF)
Manuals
MKS AA07B & AA08B Transducers Manual(758.6 kB, PDF) AA07 & AA08 Pressure Transducer Pin-outs(25.5 kB, PDF)
Drawings & CADs
AA07 & AA08 Baratron® Pressure Transducer Dimensional Drawing(1,009.5 kB, PDF)