Process Sense™ NDIR Endpoint Detector for Chamber Clean
Model: PROCESS-SENSE-NDIR
Process Sense™ NDIR Endpoint Detector for Chamber Clean
Model: PROCESS-SENSE-NDIR

Overview
Overview
The Process Sense™ endpoint sensor is a small, low-cost SiF4 sensor specifically designed for Remote Plasma Chamber Clean Endpoint detection for silicon-based CVD deposition chambers. Process Sense™ is based on infrared absorption, the only technique applicable to all plasma cleaning processes (in-situ and remote). The Process Sense™ gets mounted onto a bypass on the rough line, ensuring no effect on deposition hardware. The signal level reported by the Process Sense™, which is proportional to SiF4 concentration, can be used to determine the completion of the chamber clean process.
Technical Specs
- TypeNDIR Analyzer
- Measurement TechniqueNondispersive Infrared Sensor
- Measurement RangeSiF4 1 - 200 ppm (at 760 Torr)
- Detection Limit1 ppm SiF4 (at 760 Torr)
- Response Time1 second report rate
- Calibration Accuracy±10%
- Electrical ConnectorDB25 (DB15 adapter available)
- Power Requirements24 VDC (2 Amp)
- Dimensions38 x 12 x 13 cm (15 x 4.5 x 5 in.)
- Weight2.5 kg (5.5 lbs.)
- Analog OutputAnalog 1 (AO1): 0 - 10 V (1x SiF4 concentration), Analog 2 (AO2): 0 - 10 V (20x SiF4 concentration)
- Digital OutputFault signals
- Sample Pressure1 - 760 Torr
- Sample Temperature25 - 60°C
- FittingsNW25, NW40, NW50 (others available upon request)
Technical Specs
- TypeNDIR Analyzer
- Measurement TechniqueNondispersive Infrared Sensor
- Measurement RangeSiF4 1 - 200 ppm (at 760 Torr)
- Detection Limit1 ppm SiF4 (at 760 Torr)
- Response Time1 second report rate
- Calibration Accuracy±10%
- Electrical ConnectorDB25 (DB15 adapter available)
- Power Requirements24 VDC (2 Amp)
- Dimensions38 x 12 x 13 cm (15 x 4.5 x 5 in.)
- Weight2.5 kg (5.5 lbs.)
- Analog OutputAnalog 1 (AO1): 0 - 10 V (1x SiF4 concentration), Analog 2 (AO2): 0 - 10 V (20x SiF4 concentration)
- Digital OutputFault signals
- Sample Pressure1 - 760 Torr
- Sample Temperature25 - 60°C
- FittingsNW25, NW40, NW50 (others available upon request)
Resources & Downloads
Drawings & CADs
ProcessSense™ NDIR Dimensional Drawing(102.5 kB, PDF)